WISE-5801-MTCP

User-defined I/O & Data Logger Module with SMS Function for Modbus TCP Devices

Introduction

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development.

WISE-5801-MTCP supports an I/O expansion bus to implement various I/O functions such as D/I, D/O, A/D and D/A according to the XW-Board. In addition, WISE-5801-MTCP also supports Modbus TCP slave devices. Based on the connection ability with Modbus TCP slave devices, WISE-5801-MTCP can provide user more flexibility in application field.

WISE-5801-MTCP supports Modbus TCP/RTU protocol to make seamless integration with SCADA software available. It includes all advantages which WISE series controllers can provide. In addition, WISE-5801-MTCP provides data logger function with microSD card, it can record I/O channel value by event trigger or regular time period. The data files can be sent back by Email or FTP. WISE-5801-MTCP also features SMS sending function for alarm report and SMS command receiving function. All setting can be completed through browser.

Features

  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule enigne for logic operation
  • No more programming. Just click and get done!
  • Support IO, Counter, Timer, Schedule, Email, Recipe operations
  • Data logger and data files send back function supported
  • Modbus TCP/RTU Protocol for SCADA Software Seamless Integration
  • Support XW-Board
  • Support Modbus TCP Slave Devices(Up to 7)
  • SNTP Time Synchronization Supported
  • Support SMS (GSM: Quad-band 850/900/1800/1900 MHz)

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote Diagnosis, Testing Equipment, etc.

Hardware Specifications

System
CPU 16-bit CPU
SRAM 768 KB
Flash Memory 512 KB
microSD Expansion Support 1G/2G/4G/8G/16G/32G microSD card
RTC (Real Time Clock) Provide second, minute, hour, date of week, month and year
Watchdog Yes
Communication
Ethernet RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X)
COM 1 RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max.
COM 2 RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max. (Reserved)
LED Indicators
System LED L1 (Flash Red: System is in normal status)
L2 (Green: The microSD card is in normal status and the connection to WISE is OK (for firmware v2.9.0 or later version only))
Ethernet Link LED Yes (Green: Ethernet link detected, Flashing Green: Ethernet packet received)
Hardware Expansion
I/O Expansion Bus Yes
SMS Function
Frequency Band Quad-band 850/900/1800/1900 MHz
Mode Text and Unicode mode
Power Requirements
Protection Power Reverse Polarity Protection
Frame Ground Yes (for ESD Protection)
Input Range 12 ~ 48 VDC
Redundant Power Input Yes
Power Consumption Idle: 2.0 W; Data Link: 150 to 400 mA (peak) @ 24 VDC
Mechanical
Dimensions (W x H x D) 91 mm x 132 mm x 52 mm
Installation DIN-Rail
Environment
Operating Temperature -25 °C to +75 °C
Storage Temperature -30 °C to +80 °C
Ambient Relative Humidity 10 to 90% RH, non-condensing

Software Specifications

Functions
Rule Configuration Website Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules 3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers Delay / Timing functions.
12 Schedules Setup prescheduled routine tasks.
12 Emails Send Email messages to pre-set Email receivers.
12 SMS Send SMS to pre-set mobile phone numbers.
12 CGI Commands Send pre-set CGI commands.
12 Recipes Set up THEN/ELSE action groups.
Data Logger Set up the Data Logger configuration, include the data record format, and data file sending operation.
Modbus TCP/RTU Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
DI Channel ON, OFF, ON to OFF, OFF to ON, Change
AI Channel =, >, <, ≥, ≤ (value)
Internal Register
DI Counter =, >, <, ≥, ≤ (value), Change
Timer Timeout, Not Timeout
Schedule In Range, Out of Range
SMS Command 0, 1
Rule Status Enable, Disable
THEN / ELSE Actions
DO Channel ON, OFF, Pulse Output (apply to XW-Board only)
AO Channel Change the value
Internal Register
DI Counter Reset
Timer Start, Reset
Schedule Enable, Disable
Email Send
SMS Alarm
CGI Commands
Recipe Execute
Data Logger Start, Stop, One-Time Log
Rule Status Enable, Disable

Support I/O Module List

※ If the module name is marked in gray, it means that has been phase out.

searchSearch
Model:
I/O Type:
Functions:

I/O Type Functions Modules

Ordering Information

  • WISE-5801-MTCP CR
  • User-defined I/O & Data Logger Module with SMS Function for Modbus TCP Devices

Accessories