WISE-7105
8-channel Thermistor Input and 4-channel Isolated Digital Output PoE Module | |||||
Introduction
WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
WISE-7105 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7105 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.
This multi-function module WISE-7105 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 16-bit, 8-channel Thermistor inputs and 4-channel digital outputs. Each analog channel is allowed to configure an individual range.
Features
- Built-in Web Server for IF-THEN-ELSE rule setting
- Built-in IF-THEN-ELSE rule enigne for logic operation
- No more programming. Just click and get done!
- Support IO, Counter, Timer, Email operations
- Modbus/TCP Protocol for SCADA Software Seamless Integration
- IEEE 802.3af-compliant Power over Ethernet (PoE)
- 10/100 Base-TX Ethernet
- Support Thermistor Input
- Individual Channel Configuration
- 4-channel Digital Outputs
- 2-way Isolation/ESD Protection
Applications
Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.
Hardware Specifications
Analog Input | |
Input Channels | 8 (Differential) |
Input Type | Precon ST-A3, Fenwell U, YSI L100, YSI L300, YSI L1000, YSI B2252, YSI B3000, YSI B5000,YSI B6000, YSI B10000, YSI H10000, YSI H30000 |
Resolution | 16-bit |
Sampling Rate | 10 Sample/Sec. (Total) |
Accuracy | ±0.1% or better |
Zero Drift | ±20 μV/°C |
Span Drift | ±25 ppm/°C |
Over voltage Protection | 110 VDC/VAC |
Common Mode Rejection | 86 dB min. |
Normal Mode Rejection | 100 dB |
Open Wire Detection | Yes |
Individual Channel Configuration | Yes |
Digital Output | |
Output Channels | 4 |
Output Type | Isolated Open Collector (Sink) |
Max. Load Current | 700 mA/Channel |
Load Voltage | 5 VDC ~ 50 VDC |
Overvoltage Protection | 60 VDC |
Overload Protection | 1.4 A |
Short-circuit Protection | Yes |
System | |
CPU | 16-bit CPU |
SRAM | 512 KB |
Flash Memory | 512 KB |
EEPROM | 16 KB |
Watchdog | Yes |
Communication | |
PoE Ethernet Port | 10/100 Base-TX and automatic MDI/MDI-X |
2 Way Isolation | |
I/O | 2500 VDC |
EMS Protection | |
ESD (IEC 61000-4-2) | ±4 kV Contact for each terminal and ±8 kV Air for random point |
EFT (IEC 61000-4-4) | ±4 kV for Power Line |
LED Indicators | |
PoE | PoE On |
L1 | System Running |
L2 | Ethernet Link/Act |
L3 | Ethernet 10/100M Speed |
Power Requirements | |
Reserve Polarity Protection | Yes |
Powered from terminal block | Yes, 12 ~ 48 VDC |
Powered from PoE | Yes, IEEE 802.3af, Class1 |
Consumption | 3.0 W |
Mechanical | |
Dimensions (W x H x D) | 72 mm x 123 mm x 35 mm |
Installation | DIN-Rail or Wall mounting |
Environment | |
Operating Temperature | -25 °C ~ +75 °C |
Storage Temperature | -30 °C ~ +80 °C |
Humidity | 10 ~ 90% RH, non-condensing |
Software Specifications
Functions | |
Rule Configuration Website | Access Web server on WISE controllers to edit and upload logic rules through web browser. |
36 IF-THEN-ELSE Logic Rules | 3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions |
48 Internal Registers | Hold temporary variables and read/write data via Modbus/TCP address. |
12 Timers | Delay / Timing functions. |
12 Emails | Send Email messages to pre-set Email receivers. |
12 CGI Commands | Send pre-set CGI commands. |
12 Recipes | Set up THEN/ELSE action groups. |
8 P2P remote modules | Set up the connection information for the remote WISE modules. |
Modbus/TCP Protocol | Real time control and monitoring I/O channels and system status of controllers via SCADA software. |
IF Conditions | |
AI Channel | = 、> 、< 、 ≥ 、 ≤ (value) |
Internal Register | |
DO Counter | = 、> 、< 、 ≥ 、 ≤ (value)、Change |
Timer | Timeout、Not Timeout |
P2P | DI、AI、DI counter、DO counter、IR |
Rule Status | Enable、Disable |
THEN / ELSE Actions | |
DO Channel | ON、OFF、Pulse Output |
Internal Register | Change the value |
DO Counter | Reset |
Timer | Start、Stop |
Send | |
CGI Commands | |
Recipe | Execute |
P2P | DO(On/Off)、AO、IR |
Rule Status | Enable、Disable |
Ordering Information
- WISE-7105 CR
8-channel Thermistor Input and 4-channel Isolated Digital Output PoE Module (RoHS)
Accessories
- GPSU06U-6 : 24 V/0.25 A, 6 W Power Supply
- MDR-20-24 : 24 V/1 A, 24 W Power Supply with DIN-Rail Mounting
- NS-205 CR : Unmanaged 5-Port Industrial Ethernet Switch