WISE-7150

6-channel Isolated Sink Type Open Collector Output and 12-channel Isolated Digital Input PoE Module

Introduction

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development.

WISE-7150 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7150 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.

This module WISE-7150 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 6-channel isolated open collector outputs and 12-channel isolated wet contact digital inputs. Each output channel supports 100 mA currnet driving @ 5 ~ 30 VDC and each digital input channel supports counter input.

Features

  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule enigne for logic operation
  • No more programming. Just click and get done!
  • Support IO, Counter, Timer, Email operations
  • Modbus/TCP Protocol for SCADA Software Seamless Integration
  • IEEE 802.3af-compliant Power over Ethernet (PoE)
  • 10/100 Base-TX Ethernet
  • 2-way Isolation/ESD Protection
  • DO Type: 6 Isolated Open Collectors (Sink Type)
  • DI Type: 12 Isolation Wet Contact (Sink/Source)

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote Diagnosis, Testing Equipment, etc.

Hardware Specifications

Digital Input
Input Channels 12
Input Type Wet Contact (Sink, Source)
On Voltage Level +10 VDC ~ +50 VDC
Off Voltage Level +4 VDC Max.
Input Impedance 10 kΩ
Counters Max. Count 65535 (16 bits)
Max. Input Frequency 50 Hz
Min. Pulse Width 10 ms
Overvoltage Protection +70 VDC
Digital Output
Output Channels 6
Output Type Open Collector (Sink)
Max. Load Current 100 mA/channel at 25 °C
Output Voltage +5 VDC ~ +30 VDC
Overvoltage Protection 60 VDC
Overload Protection 1.3A
Short-circuit Protection Yes
System
CPU 16-bit CPU
SRAM 512 KB
Flash Memory 512 KB
EEPROM 16 KB
Watchdog Yes
Communication
PoE Ethernet Port 10 / 100 Base-TX and Automatic MDI/MDI-X
2 Way Isolation
I/O 2500 VDC
EMS Protection
ESD (IEC 61000-4-2) ±4 kV Contact for each terminal and ±8 kV Air for random point
EFT (IEC 61000-4-4) ±4 kV for Power Line
LED Indicators
PoE PoE On
L1 System Running
L2 Ethernet Link/Act
L3 Ethernet 10/100M Speed
Power Requirements
Reserve Polarity Protection Yes
Powered from terminal block Yes, 12 ~ 48 VDC
Powered from PoE Yes, IEEE 802.3af, Class1
Consumption 2.4 W
Mechanical
Dimensions (W x H x D) 72 mm x 123 mm x 35 mm
Installation DIN-Rail or Wall mounting
Environment
Operating Temperature -25 °C ~ +75 °C
Storage Temperature -30 °C ~ +80 °C
Humidity 10 ~ 90% RH, non-condensing

Software Specifications

Functions
Rule Configuration Website Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules 3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers Delay / Timing functions.
12 Emails Send Email messages to pre-set Email receivers.
12 CGI Commands Send pre-set CGI commands.
12 Recipes Set up THEN/ELSE action groups.
8 P2P remote modules Set up the connection information for the remote WISE modules.
Modbus/TCP Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
DI Channel ON、OFF、ON to OFF、OFF to ON、Change
Internal Register = 、> 、< 、 ≥ 、 ≤ (value)
DI Counter = 、> 、< 、 ≥ 、 ≤ (value)、Change
DO Counter
Timer Timeout、Not Timeout
P2P DI、AI、DI counter、DO counter、IR
Rule Status Enable、Disable
THEN / ELSE Actions
DO Channel ON, OFF, Pulse Output
Internal Register Change the value
DI Counter Reset
DO Counter
Timer Start、Stop
Email Send
CGI Commands
Recipe Execute
P2P DO(On/Off)、AO、IR
Rule Status Enable、Disable

Ordering Information

  • WISE-7150 CR
  • 6-channel Isolated Sink Type Open Collector Output and 12-channel Isolated Digital Input PoE Module (RoHS)

Accessories

  • GPSU06U-6 : 24 V/0.25 A, 6 W Power Supply
  • MDR-20-24 : 24 V/1 A, 24 W Power Supply with DIN-Rail Mounting
  • NS-205 CR : Unmanaged 5-Port Industrial Ethernet Switch (RoHS)
  • NS-205PSE-24V CR : Unmanaged 5-Port Industrial PoE Ethernet Switch (RoHS)